Product Features
-
Manual
-
| ISP-108/116 | ||||
---|---|---|---|---|---|
Electrical Features | |||||
Categories | MIN | TYP | MAX | UNIT | |
Device Specifications | DC Breakdown in Volts (@100V/s) | 240 | 300 | 360 | V |
Impulse Breakdown in Volts (@100V/μs) | - | - | 700 | V | |
Impulse Breakdown in Volts (@1 Kv/μsec) | 1010 | - | 800 | V | |
Insulation Resistance |
| - | - | Ω | |
Capacitance (@1MHz) | - | - | 1.5 | pf | |
Arc Voltage (on state Voltage) (@1Amp Min) | - | 15 | - | V | |
Surge Life (@500A 10/1000μs) | 400shots | - | |||
Nominal Impulse Discharge Current (8/20μs) | 10 shots (@20kA) | - | |||
LifeRatings | Nominal AC Discharge Current (10x1sec @50-60Hz) | - | 20 | - | A |
AC Dischage Current (9 cycle @50Hz) | - | 100 | - | A | |
DC Holdover Voltage | - | 135 | - | V | |
Max Impulse Discharge Current (1 Application @ 10/350μs) | - | 2.5 | - | kA | |
Channel | ISP-108 | 8CH | |||
ISP-116 | 16CH | ||||
General Features | |||||
Weight(Set) | 3.56kg | ||||
Dimension(Set) | 300(W) x 376(H) x 47(D)mm |